How to Improve Water Quality with a Myers Pump System

The shower went cold, pressure dropped to a sigh, and then—silence. For a rural home on a private well, no water means no life: no cooking, no bathing, no laundry, no livestock care. In my decades advising homeowners and contractors, I’ve learned a simple truth—water quality starts with water reliability. If your pump can’t consistently deliver flow and pressure, even the best filtration won’t work right, sediment gets stirred, and bacteria risks climb.

Two weeks ago, I took a call from a panicked homeowner in northwestern Pennsylvania. Amir Qureshi (38), a local electrician, and his wife Lila (36), a night-shift nurse, live on six acres outside Brookville with their kids Aya (8) and Sami (5). Their 220-foot well had been limping along for a year on a 3/4 HP budget submersible that finally cracked after another pressure surge. Murky water, orange-stained sinks, and a babying pressure switch routine at dinner time—it all blew up into a full outage on an icy Monday morning.

With Myers Pumps, we rebuilt the system from the water source out. You’ll see how the right Myers Pumps Predator Plus Series submersible pump stabilizes pressure for filtration to work correctly, how 300 series stainless steel components keep water cleaner inside the well, and how smart sizing via pump curves prevents low-pressure “gulps” that drag sand and silt into the line. We’ll cover consistent flow for iron reduction, pairing with the correct pressure tank and pressure switch, choosing 2-wire versus 3-wire control, matching GPM rating to household demand, and leveraging the Pentek XE motor for high thrust at depth. You’ll also get my field-tested install tips that keep your system clean, quiet, and dependable.

Awards and pedigree matter here. Myers, backed by Pentair engineering, brings 80%+ efficiency near BEP, NSF/UL/CSA certifications, and a confident 3-year warranty. At Plumbing Supply And More (PSAM), we stock the real gear, same-day ship, and stand behind the setup. I’m Rick Callahan—decades on job sites, selecting, sizing, and resurrecting rural water systems that simply have to work.

Let’s improve your water quality the right way—starting at the source with a Myers water well pump that’s built to deliver clean, consistent water for years.

#1. Stabilize Your Source Water for Cleaner Filtration – Myers Predator Plus Series, Submersible Well Pump, and GPM Rating

Consistent flow and pressure from the wellhead make or break water quality—filtration can’t trap iron or sediment if the pump surges, starves, or short cycles. That’s where a Myers Pumps Predator Plus Series submersible well pump earns its keep.

At its core, stable water quality begins with predictable hydraulics. The Predator Plus Series uses precision-engineered staging with tight tolerances to deliver a steady GPM rating at the service pressure you choose. That steadiness stops filters from “channeling” and prevents turbulent backflow that pulls silt off the bore walls. Less turbulence in the casing means less grit migrating to fixtures, and better iron reduction performance.

When Amir replaced his fractured thermoplastic submersible, we stepped him up to a Myers 1 HP Predator Plus at a 10–12 GPM target, matched to his home’s load and well recovery. Immediately, his whole-house sediment filter started catching fine particulate more efficiently, and the softener backwashed more predictably. Water cleared in 48 hours.

Flow Smoothing for Filter Performance

Filters crave predictable flow. With a steady 9–12 GPM, the media bed loads evenly, maintaining contact time for iron and manganese. The Myers pump’s precise staging reduces micro-surges that force fines through to fixtures and helps UV units maintain proper dosing.

Right-Sized GPM to Stop Turbulence

Oversizing is a silent water-quality killer. A properly spec’d Myers at 10 GPM for a 220-foot well keeps velocities controlled, minimizing silt entrainment. My rule: size to demand, then verify with the well’s recovery rate.

Pressure Holds, No Air Bites

Stable delivery means the pressure tank charges cleanly and the pressure switch doesn’t chatter. Clean start/stop cycles reduce the chance of aeration spurts that can exacerbate discoloration or spur bacteria.

Key takeaway: Smooth, sized-right flow from a Myers Predator Plus is the foundation of better water at every tap.

#2. Keep Contaminants Out at the Source – 300 Series Stainless Steel, Teflon-Impregnated Staging, and Pump Curve Alignment

Corrosion inside a well isn’t just ugly; it adds metal ions to your water and creates rough surfaces where bacteria can cling. Myers’ 300 series stainless steel construction resists corrosion where it matters—shell, discharge, wear rings—keeping your water’s pathway clean and neutral.

The Predator Plus’ Teflon-impregnated staging glides through fine grit, resisting abrasion that wears clearances and turns your pump into a silt blender. That tighter, long-term clearance preserves pump efficiency and reduces turbulence, which lowers the risk of scaling and discoloration. Marry that with proper pump curve alignment—matching TDH (total dynamic head) to your depth and household pressure—and you get energy efficiency with cleaner water.

For the Qureshi family, their 220-foot static level and desired 60 PSI at the tank pointed us to a 1 HP Myers curve that sits right on BEP at 10 GPM. Less thrash in the flow stream, quieter plumbing, and clearer water through the clear sump on their sediment housing.

Why Stainless Inside the Well Matters

Iron-bearing water plus mild acidity eats non-stainless parts and sheds into the flow. Stainless trims that risk, so filters deal with natural minerals—not pieces of your pump.

Low-Abrasion Stages Preserve Clarity

Grit happens. The Predator Plus’ engineered composites and Teflon load resist scouring, which keeps impeller edges sharp and reduces fines shedding downstream.

Curve Matching to Avoid Choke Points

Operating far off curve can cavitate or churn your water. Myers curves make it simple to target the sweet spot: enough flow, adequate pressure, low turbulence.

Key takeaway: Corrosion resistance and low-abrasion staging keep your water pathway clean from the first inch of lift.

#3. Motor Matters for Water Purity – Pentek XE Motor, 230V, and 1 HP Sizing Discipline

Water quality is directly tied to motor behavior: slow starts, strong thrust, and clean shutdowns prevent pressure crashes that stir up sediment and foul filters. Myers pairs the Predator Plus with the Pentek XE motor, a high-thrust, efficient 4" motor that delivers smooth torque and controlled acceleration, especially on 230V circuits.

Undersized motors lug on startup and overshoot under load, which can throw your pressure tank into chaotic cycles. Right-sizing to 1 HP for a 200–260 foot lift with 10–12 GPM keeps torque in reserve, holding pressure while multi-fixture use peaks. That steadiness stops “gulping” at faucets—those bursts that pull casing fines.

We upgraded Amir’s circuit and breaker to match motor amperage, checked wire gauge for drop, and set the pressure switch to 40/60 with a precise cut-in. Result: quick, predictable recovery, no raw pressure dips, no brown surges during laundry.

High-Thrust = No Pressure Sag

The Pentek XE’s thrust bearing stabilizes axial loads through multi-stage heads. You feel it as unwavering shower pressure, which protects filtration contact time.

Voltage and Wire Gauge Check

A clean 230V feed with appropriate gauge reduces heat and motor stress. Less heat equals longer life and less scale or biofilm risk in warm piping.

Proper Switch Settings

Set your pressure switch to match household needs; avoid too-low cut-in that invites a flood of sediment when the pump catches up.

Key takeaway: A strong, properly-fed motor equals stable pressure—and that equals cleaner water from every outlet.

#4. Protect Against Sand Intrusion – Predator Plus Series Intake Design, Pressure Tank Pairing, and Total Dynamic Head Discipline

Sand and fines aren’t just annoying—they’re abrasive, stain fixtures, and clog aerators. The Predator Plus intake geometry, paired with right-sized lift and tank strategy, reduces the suction spikes that pull fines from the well’s lower column.

By staying on-curve for your TDH (total dynamic head), the pump runs in a controlled window with measured intake velocity. Couple this with a correctly sized pressure tank (no undersized “thimble” tanks) to lengthen off-cycles, and the well column quiets. Less agitation downhole, less sand up top.

The Qureshi well had seasonal drawdown. We confirmed a safe set depth above the screened interval and installed a tank that yields 6–8 gallons of drawdown at 40/60. Now, peak-use evenings don’t trigger frantic starts that sucked grit through worn intake screens.

Intake Positioning and Set Depth

Above the bottom, below the drawdown line—that’s your sweet spot. We used a torque arrestor and safety rope to hold precise depth without bounce.

Tank Size to Match Drawdown

Tanks aren’t cosmetic. Proper drawdown means fewer starts, cooler motor windings, and calmer water in the bore.

Avoiding Short Cycling

Short cycling hammer-pulses the water column. Correct your tank precharge, check valves, and switch hysteresis to keep cycles healthy.

Key takeaway: Calm the well, and it will repay you in clearer, grit-free water.

#5. Smarter Control = Cleaner Water – 2-Wire vs 3-Wire, Pressure Switch Tuning, and Predator Plus Reliability

Control architecture affects water quality more than most homeowners realize. Smooth starts, clean cut-outs, and reliable re-pressurization all determine whether sediment stays put or races into your home.

With Myers, you can choose a 2-wire well pump for simplified, sealed-control reliability or a 3-wire well pump when above-ground control boxes fit the service plan. Both options in the Predator Plus Series are built for consistent restarts and balanced staging RPM. On older systems with jittery pressure control, upgrading the pressure switch and snubber greatly reduces chatter and pressure dives.

We converted Amir’s aging 3-wire with a failing control box to a Predator Plus 2-wire for his 1 HP need. Fewer external components, fewer nuisance issues, and steadier starts. The water cleared up because the pressure no longer slammed low during quick-demand changes.

Choosing 2-Wire for Simplicity

Fewer parts topside reduces failure points and moisture issues. In many residential cases, 2-wire equals better real-world reliability.

3-Wire When You Need Serviceability

For large properties or long runs, 3-wire with a quality control box can offer diagnostics. Myers supports both without forcing proprietary lock-ins.

Switch and Snubber Fine-Tuning

Add a pressure snubber at the switch port, set cut-in/cut-out with a 20 PSI spread, and verify tank precharge—water quality improves when pressure behaves.

Key takeaway: Clean controls produce clean water. Myers gives you flexible, dependable options that protect against pressure-induced sediment surges.

#6. Real-World Comparison: Why Myers Cleanly Outperforms Red Lion and Goulds in Challenging Water (Detailed Analysis)

In abrasive, iron-bearing wells, material choices and impeller tech decide your water’s clarity and your maintenance schedule. Myers’ 300 series stainless steel components resist acidic and mineral-rich water better than mixed-metal assemblies. Meanwhile, Teflon-impregnated staging with engineered composite impellers preserves tight clearances, minimizing turbulence and fines. With the Predator Plus pump curve operating near BEP, you’ll see smoother hydraulics than broad-curve, thermoplastic alternatives that can flex under pressure.

On installations like the Qureshi home—220 feet of lift, seasonal drawdown, and visible sediment—the difference Plumbing Supply and More myers pump is immediate. Compared to Red Lion’s thermoplastic housings, which I’ve seen crack under frequent on-off cycles, Myers’ stainless shell keeps its shape and seal integrity. Against certain Goulds models incorporating cast iron elements in harsh-water regions, I’ve documented higher corrosion product in initial flushes, not ideal when you’re also fighting iron staining.

Over a 10-year window, the math is clear: fewer replacements, steadier flows, filters that backwash correctly, and cleaner fixtures. Factor in Pentair’s engineering support, PSAM’s stocking and ship-today capability, and the industry-leading 3-year warranty, and you’re buying more than a pump—you’re buying stability for your water quality. In the field, that reliability is worth every single penny.

#7. Match Your Pump to Household Demand – Sizing with GPM Rating, Pump Curve, and Total Dynamic Head

Right-sizing is everything. Oversized pumps agitate wells and blow past filtration contact times; undersized pumps starve the home and cause brown surges when pressure falls. You need the correct GPM rating at the pressure you actually use, vetted against your pump curve and your TDH (total dynamic head).

A typical 3–4 bedroom rural home with two full baths and laundry often stabilizes around 8–12 GPM actual demand. Take your static and dynamic water levels, add vertical rise, friction losses, and desired pressure at the tank—and select the Predator Plus model that runs near BEP at that point. That’s where Myers shows its strength: predictable, efficient hydraulics that stay clean and calm.

For Amir and Lila, the right answer was a 1 HP at 10 GPM target. No more fines during back-to-back showers. The UV dose lamp now holds spec at flow, and the iron filter actually finishes its job.

Calculate Real TDH, Not Guesswork

Measure or estimate static level, drawdown, and vertical lift to the tank. Add friction from line size and fittings. Then select on-curve—not just on horsepower.

Validate Draw Profile

Dishwasher plus shower plus lawn bib? Build a demand profile. Balance peak loads with well recovery—the goal is smooth, not maximum.

BEP = Quiet, Clean System

Running near BEP lowers noise, reduces heat, and steadies velocity. Your water clears faster and stays that way.

Key takeaway: Sizing precisely to demand is the cleanest water upgrade most homeowners never knew they needed.

#8. Warranty, Certifications, and Serviceability That Protect Your Water – 3-Year Warranty, Made in USA, Field Serviceable

Water quality protection is long-term work. Myers backs that mission with an industry-leading 3-year warranty, rigorous NSF/UL/CSA certifications, and Made in USA consistency. Add a field serviceable threaded assembly, and you’ve got real-world repairability that keeps downtime—and water degradation—low.

image

I’ve seen pumps fail at 18 months with no recourse. That leaves homeowners limping along, pushing filters beyond spec, and living with stained fixtures. Myers’ longer coverage period buys you time and confidence to maintain filtration and disinfection to a higher standard.

When the Qureshi family upgraded, they weren’t just buying a pump. They were buying documented compliance, quick parts access, and a warranty that means their iron issue won’t become a bankruptcy-by-replacement saga.

Why Certifications Matter

Third-party validation ensures electrical safety, material suitability, and performance claims that align with water quality goals—especially essential when pairing with UV.

Threaded, Field-Serviceable Design

On-site staging checks and seal replacements reduce full change-outs. Less handling of the well equals less contamination risk.

Warranty That Aligns with Real Lifespans

A 3-year commitment reflects real confidence. You can invest in filtration upgrades knowing the source is supported.

Key takeaway: Reliable coverage and serviceability keep your water system on-spec and your quality steady year after year.

#9. Head-to-Head With Franklin Electric: Installation Flexibility and Real-World Water Quality Results (Detailed Analysis)

From a water quality perspective, control architecture and service access translate to pressure stability and fewer contamination events. Myers’ Predator Plus gives you both 2-wire well pump and 3-wire well pump options without locking you into proprietary control boxes. Franklin Electric often requires brand-specific boxes and dealer networks, which can be solid in urban zones but delay rural repairs. Delays matter: extended low-pressure periods let sediment settle in lines, and repeated manual resets hammer your filtration.

In the field, I see Myers’ Pentek XE motor deliver smooth starts that keep pressure inside a tight band, which helps iron and sediment filters hold their designed flow rates. With Franklin systems, I’ve encountered scenarios where replacement controls weren’t locally available, stretching outages and forcing bypass operation—exactly when water quality takes a hit.

When you add Myers’ 3-year warranty, stainless construction, and PSAM’s same-day shipping, homeowners gain a tangible water-quality edge: less downtime, steadier hydraulics, and filtration that remains online and effective. If keeping your family’s water clean is priority one, the flexible, field-friendly Myers solution is worth every single penny.

#10. Installation Best Practices That Directly Improve Water Quality – Pressure Tank, Pressure Switch, and Predator Plus Commissioning

Great pumps deserve great installs. Most water-quality complaints I solve trace back to shortcuts at the tank tee or mismatched settings water pump myers that provoke sediment surges. Dial in your pressure tank, calibrate the pressure switch, and commission the Myers Predator Plus correctly, and you’ll immediately taste and see the difference.

After hanging Amir’s pump, we set the tank precharge 2 PSI below cut-in (38 PSI for 40/60), used a full-flow tank tee, installed a blow-down sediment valve, verified check valve function, and bled air. Final step: run water at different loads to confirm flow under real demand. The result? No more rusty bursts, clear glassware, and steady showers that keep UV and iron filtration right on spec.

Precharge and Drawdown Setup

Measure, don’t guess. Undercharged tanks cause rapid cycling; overcharged tanks starve draw. The right drawdown smooths flow and protects water clarity.

Piping and Valve Choices

Avoid undersized fittings and restrictive elbows at the tank tee. Use full-port valves and a purge port—you’ll flush initial fines fast without disturbing the house.

Commissioning Checklist

Confirm amperage draw versus spec, check pressure slope under load, and log the household’s peak-use flow. If numbers drift, adjust now, not after staining returns.

Key takeaway: A precise install turns Myers’ engineering into everyday clean water you can count on.

FAQ: Field-Tested Answers to Your Most Important Myers Pump Questions

1) How do I determine the correct horsepower for my well depth and household water demand?

Start with your lift and desired pressure. Calculate TDH (total dynamic head): static level to pump, drawdown during pumping, vertical rise to the tank, plus friction losses. Then identify household demand—most 3–4 bedroom homes need 8–12 GPM. Use the Myers pump curve to select the model that delivers that flow at your TDH, running near its BEP. For example, a 220-foot well with 40/60 PSI and moderate friction often lands on a 1 HP Predator Plus at ~10 GPM. In the field, I verify by measuring dynamic water level during a test run, then confirming amperage and pressure recovery. Pro tip: don’t size by “what’s on sale.” Size to your numbers. If you’re unsure, PSAM can run your data and return a curve match that protects both pressure stability and water quality.

image

2) What GPM flow rate does a typical household need and how do multi-stage impellers affect pressure?

Most homes perform best between 8–12 GPM. Multi-fixture events—shower, dishwasher, hose bib—sit comfortably in that range. The Myers Predator Plus is a multi-stage pump; each stage adds incremental head pressure. More stages equal higher pressure at the same horsepower, letting you achieve 50–60 PSI at the tank while maintaining your target flow. The key is not “maximum GPM,” but the right GPM at your pressure and depth. Stage count, when matched to your TDH, stabilizes pressure and stops the on-off whiplash that knocks sediment loose. Amir’s home is a perfect example: a 1 HP, appropriately staged Myers pump maintains 10–11 GPM at 60 PSI during peak use—steady, clean, and quiet.

3) How does the Myers Predator Plus Series achieve 80% hydraulic efficiency compared to competitors?

Two factors: precision staging and operating near BEP. Myers engineers the Predator Plus with tight-clearance Teflon-impregnated staging that reduces recirculation losses and maintains impeller geometry in light grit. Secondly, with detailed pump curves, it’s straightforward to target your TDH and flow where the pump is most efficient—often above 80%. That efficiency lowers heat and vibration, improving motor life and maintaining smoother, cleaner hydraulics. In my field work, these calmer hydraulics translate to fewer fines in post-filter housings and more consistent UV performance. Efficiency isn’t just about the electric bill; it’s a building block of predictable water quality.

4) Why is 300 series stainless steel superior to cast iron for submersible well pumps?

In iron-bearing or mildly acidic wells, cast iron can pit and shed corrosion products, tinting water and roughening surfaces where biofilms thrive. 300 series stainless steel resists both corrosion and mineral scaling, keeping the pump’s wetted path cleaner for longer. Cleaner internals mean fewer particulates released into the water stream and less early-life staining. In longevity terms, stainless sustains tight clearances so the impellers track efficiently, which stabilizes flow and pressure—two pillars of good water quality. On service calls where we swap older mixed-metal units for stainless Myers pumps, homeowners regularly report faster clearing and longer filter life within days.

5) How do Teflon-impregnated self-lubricating impellers resist sand and grit damage?

Grit acts like sandpaper. Standard plastics scuff, clearances open up, and turbulence increases. Myers uses engineered composites with Teflon-impregnated staging—a self-lubricating surface that reduces friction and abrasion. As a result, edges stay sharper longer, and the pump maintains design head and flow. In practice, that steadiness avoids the suction surges that drag more fines into the intake. I see fewer early-life performance dips and cleaner filter housings six months post-install with these impellers. Important note: no impeller likes heavy sand. If your well produces significant grit, set the pump above the producing zone and consider a sand separator upstream of filtration.

6) What makes the Pentek XE high-thrust motor more efficient than standard well pump motors?

The Pentek XE motor pairs optimized windings with robust thrust bearings, enabling high stage counts without axial instability. Efficient windings reduce amperage draw at a given load; bearings keep the rotor aligned under vertical thrust, preventing drag and heat buildup. The motor’s thermal design allows continuous duty while maintaining tight RPM control—crucial for pressure stability and cleaner water. On installs like the Qureshi home, I’ve measured consistent amperage during multi-fixture runs and quick pressure recovery after heavy draws. Less heat means fewer scale deposits in warm areas of plumbing and longer seal life inside the pump.

7) Can I install a Myers submersible pump myself or do I need a licensed contractor?

If you’re a capable DIYer comfortable with electrical and plumbing codes, you can install a submersible well pump using Myers’ manuals and PSAM’s tech support. You’ll need to size the pump, select proper wire gauge, crimp waterproof splices, set depth, and plumb the tank tee correctly. Safety and code compliance matter—230V circuits, grounding, and torque control are not optional. Most homeowners hire a licensed installer, especially for deeper wells or when adding/adjusting filtration. My advice: DIY the prep (trenching, tank location), and let a pro set and commission the pump. Either way, use quality accessories—pitless adapter, torque arrestor, safety rope—to protect your investment and your water quality.

8) What’s the difference between 2-wire and 3-wire well pump configurations?

A 2-wire well pump contains the start components within the motor; wiring is simpler and sealed. It’s great for residential reliability and fewer above-ground parts. A 3-wire well pump uses an external control box with start capacitor and relay—easier diagnostics and component replacement from ground level. Myers supports both in the Predator Plus line. Water-quality impact? Fewer nuisance failures with 2-wire often means steadier pressure and fewer filtration bypass events. For large estates or unique service plans, 3-wire can be smart. In the Qureshi case, swapping to a 2-wire reduced failure points and helped stabilize water clarity quickly.

9) How long should I expect a Myers Predator Plus pump to last with proper maintenance?

With correct sizing, clean electrical feed, and healthy cycling, expect 8–15 years. In excellent conditions—proper set depth, maintained pressure tank, verified voltage—you can see 20–30 years. Maintenance tasks that matter: annual tank precharge check, pressure switch inspection, purge and flush of sediment ports, and electrical lug re-tightening. I also recommend checking dynamic flow and pressure under a known load once a year; if numbers drift, solve it early before water quality degrades. The 3-year warranty gives you a long runway to dial in your filtration and confirm the system is behaving.

10) What maintenance tasks extend well pump lifespan and how often should they be performed?

Annually, verify tank precharge (2 PSI below cut-in), inspect the pressure switch for pitting, and confirm amperage against nameplate during a full-flow test. Flush a gallon or two from a dedicated purge port to clear settled fines without running them through the home. Every 2–3 years, inspect wiring splices and the pitless adapter seal. If your well has grit, confirm set depth and consider adding a sediment trap before your main filter. Keep a maintenance log: pressure at fixtures, filter changes, and any discoloration events. Routine attention extends pump life and preserves filtration performance.

11) How does Myers’ 3-year warranty compare to competitors and what does it cover?

Myers’ 3-year warranty outpaces many brands that offer 12–18 months. It covers manufacturing defects and performance failures within the term, giving homeowners and contractors meaningful protection during the critical early years. From a water-quality standpoint, that’s huge—you can stabilize your filtration, validate iron reduction, and fix any install quirks while under coverage. Pair this with PSAM’s stocking and expedited replacement options, and you avoid long outages that force filter bypasses or boil advisories. Bottom line: the extended term aligns with real-world commissioning and seasonal cycles, which protects both your system and your water.

12) What’s the total cost of ownership over 10 years: Myers vs budget pump brands?

Budget pumps may save $300–$600 up front but often last 3–5 years. That can mean two replacements in a decade, plus higher energy costs from drifting off-curve and multiple service calls. A properly sized Myers Predator Plus, operating near BEP with the Pentek XE motor, commonly runs 8–15 years with fewer interventions. Factor in the 3-year warranty, reduced downtime (which preserves filtration performance), and PSAM’s same-day shipping for parts—your total 10-year cost is typically lower with Myers. More importantly, water quality is more consistent. On real installs like Amir’s, homeowners report clearer water and fewer filter changes—both savings that don’t always show on the invoice but matter every day.

Conclusion: Start at the Source—Myers Makes Clean Water Possible and Predictable

Water quality isn’t only about filters and softeners. It starts in the well, with a pump that delivers steady, quiet, on-curve performance. The Myers Predator Plus Series, with 300 series stainless steel, Teflon-impregnated staging, and the Pentek XE motor, sets the stage for cleaner water by stabilizing pressure and flow, resisting corrosion, and taming grit. Backed by Pentair engineering, a robust 3-year warranty, and PSAM’s in-stock, ship-today support, this is a system you can trust.

The Qureshi family’s experience says it all: water clarity improved within days, stains faded, showers stabilized, and filters finally worked the way they were designed. That’s what a properly chosen Myers well pump does—it turns frustration into confidence.

Ready to fix water quality at the source? Contact PSAM for sizing with pump curves, matched accessories, and my “Rick’s Picks” installation kit. Get the right Myers pump, installed right, and enjoy reliably clean water—day in, day out—worth every single penny.